Background: Intravenous cannulation is an essential skill across all patient groups and a vital route for delivering time-critical and life-saving treatment. It is a core competency for junior doctors and one that clinicians continue to refine throughout their careers. In neonates and paediatrics, cannulation is especially challenging: veins are small and prone to rolling, the hand is difficult to position and stabilise, and technique differs from adult practice. Our previous session taught ultrasound-guided cannulation to build clinicians' confidence with the ultrasound machine and give them an alternative when initial attempts fail. Feedback was very positive, but participants also asked for a clearer, simpler session to consolidate and practise the fundamentals. We therefore adapted our teaching to focus on the basics of neonatal and paediatric cannulation: the equipment, how to position and hold the patient's hand, and the key differences between neonatal and adult cannulation.
Method: Participants ranged from medical students to foundation trainees to GP trainees. We built a low-fidelity neonatal hand model from reused materials that would otherwise have been discarded; examination gloves and plastic tubing from used medication packaging. Two gloves were layered, and the inner glove was inflated with air to recreate the shape and resistance of a small hand. A short plastic tubing was placed between the two layers to act as a vein, with the outer glove acting as the skin. Participants practised inserting the cannula through the "skin" and into the "vein", while the inflated inner glove stayed in shape, so they could practise positioning and stabilising the hand throughout the procedure. The session covered aseptic non-touch technique (ANTT), equipment and preparation, hand positioning, vein anatomy, angle of insertion, and most importantly securing the cannula. A facilitator then gave a live demonstration on a patient, using interactive questioning to help participants apply what they had just learnt. Participants after the session rated their confidence before and after the session using a 5-point Likert scale questionnaire.
Results: Participants rated the model as realistic for practising technique, reporting that it recreated the tactile resistance of skin and veins and supported correct hand positioning. All participants reported increased confidence, with mean self-rated confidence rising from 1.1 to 4.9 on a 5-point Likert scale. Each model cost under £0.10 to make, using two examination gloves and recycled medication tubing, compared with approximately £400–£1,500 for a single commercial neonatal cannulation training arm.
Conclusion: Learner feedback from advanced teaching can usefully guide the design of further teaching sessions. Reusing discarded clinical materials offers a resourceful, low-cost, and environmentally sustainable way to teach the basics of neonatal cannulation. It is easy to replicate in other units and fits wider NHS goals on reducing clinical waste.